AVL portable PETROL EMISSION TESTERS

 Petrol 

Diesel Combined Portable 4/5 Gas


DIGAS 440

The DiGas 440 is a portable petrol emission tester that can operate on 12 volts or 240 volts.  It is available in 2, 3, 4, 5 gas options as well RPM & oil temp measurement options.  Accurate to MOT test standards but not approved for MOT testing.

Available versions:

Cat.No.:

DIGAS 2000 - 2 Gas

CO / HC

DIGAS 2000 

DIGAS 440 - 3 Gas

CO / CO2 / HC

DIGAS 440 3G

DIGAS 440 - 4 Gas

CO / CO2 / HC / O2 / Lambda

DIGAS 440 4G

DIGAS 440 - 5 GAS

CO / CO2 / HC / O2 / NOx / Lambda

DIGAS 440 5G

DIGAS 440 - 3 Gas / RPM/°C

CO / CO2 / HC

DIGAS 440 3G R

DIGAS 440 - 4 Gas / RPM/°C

CO / CO2 / HC / O2 / Lambda

DIGAS 440 4G R

DIGAS 440 - 5 GAS /RPM/°C

CO / CO2 / HC / O2 / NOx / Lambda

DIGAS 440 5G R

 

Technical data:

 

Power supply :

11-22 V from onboard supply (option)
100 -240 V AC, 50/60 Hz with power supply unit

CO:

0 -10% vol.,
Resolution : 0.01% vol.

HC :

0 - 20000 ppm vol.,
Resolution < 2000 : 1 ppm vol.
Resolution > 2000 : 10 ppm vol.

CO2 :

0 - 20% vol., 
Resolution : 0.1 % vol

O2 :

0 - 22 % vol., 
Resolution : 0.01 % vol.

NOx :

0 - 5000 ppm vol., 
Resolution : 1 ppm vol.

Lambda :

0 - 9.999, calculation of the 4 Gas values,
Resolution : 0.001

Engine speed :

400 - 6000 min -1 , 
Resolution : 1 min -1

Oil-temperature:

-30 °C - 125 °C, 
Resolution : 1 °C.

Display :

LCD 62 mm x 44 mm,

Ports :

RS 232 for serial printer or PC

Dimensions (WxDxH) :

approx. 27 x 34 x 8.5 cm

Net weight :

approx. 4.5 kg

Subject to technical changes without notice